1 / 6AFEX-950 Automatic Ambient Air Quality Monitoring Station (Gas Analyzer)
1 pc · O₃ · ppb · Ozone · 0 ~ 5000 ppb · 50 ppm NH₃ · 2 L
- Power supply
- 1 pc
- 8
- O₃ · ppb · Ozone · 0 ~ 5000 ppb
- NH₃
- 50 ppm NH₃ · 2 L
- PTFE / Teflon sample line
- 10 m
- Particulate filter (0.5–1 µm)
- 3 pcs
- Parameter
- 1 year
Overview
Key features
- 1
O₂ · % VOL · Oxygen concentration · 0 ~ 25 % VOL
- 2
PM2.5 · µg/m³ · Fine particulate matter · 0 ~ 500 µg/m³
- 3
PM10 · µg/m³ · Particulate matter · 0 ~ 3000 µg/m³
- 4
CO · ppm · Carbon monoxide · 0 ~ 1000 ppm
About the equipment
Project Significance and Expected Results

- Continuous 24/7 real-time monitoring of ambient air conditions becomes possible.
- When the concentrations of harmful gases and particulate matter (PM) exceed regulatory limits, a rapid alert system is triggered.
- Monitoring data are transmitted automatically to the state environmental monitoring platforms integrated with the system.
- The preparation and analysis of environmental reports are fully automated.
- The enterprise's level of environmental safety, its compliance with legal requirements, and its transparency and credibility before regulatory authorities increase significantly.
System Functionality

- Continuous 24/7 automatic measurement of gas concentrations in ambient air.
- High-precision monitoring of PM2.5 and PM10 fine particulate matter.
- Analysis of environmental factors (temperature, humidity, wind speed and direction, atmospheric pressure, etc.) using a full-featured meteorological module.
- Real-time data collection, transmission, storage and multi-level analysis.
- Full API integration with state environmental monitoring platforms.
- Support for Modbus TCP/IP, RS-485 and other industrial communication protocols.
- Automatic generation of 20-minute, hourly, daily, monthly and annual reports.
- Rapid alerts and notifications via Telegram, SMS and e-mail.
- Secure and convenient use through a multi-user, role-based management system.
- Access control system preventing unauthorized entry to the monitoring post area.
- Additional monitoring functions that ensure uninterrupted system operation and enhance security.
Modern Communication and Data Transmission System

Air Quality Monitoring Device Sensors

- 1
- O₂ · % VOL · Oxygen concentration · 0 ~ 25 % VOL
- 2
- PM2.5 · µg/m³ · Fine particulate matter · 0 ~ 500 µg/m³
- 3
- PM10 · µg/m³ · Particulate matter · 0 ~ 3000 µg/m³
- 4
- CO · ppm · Carbon monoxide · 0 ~ 1000 ppm
- 5
- CO₂ · ppm · Carbon dioxide · 0 ~ 5000 ppm
- 6
- H₂S · ppm · Hydrogen sulfide · 0 ~ 100 ppm
- 7
- NH₃ · ppm · Ammonia · 0 ~ 100 ppm
- 8
- O₃ · ppb · Ozone · 0 ~ 5000 ppb
- 9
- NO₂ · ppm · Nitrogen dioxide · 0 ~ 20 ppm
- 10
- SO₂ · ppm · Sulfur dioxide · 0 ~ 20 ppm
- 11
- HCl · ppm · Hydrogen chloride (HCl) vapors · 0 ~ 50 ppm
- 12
- Cl₂ · ppm · Chlorine gas · 0 ~ 10 ppm
- 13
- Temperature · °C · Ambient temperature · −45 ~ +125 °C
- 14
- Humidity · % RH · Relative humidity · 0 ~ 99 % RH
Technical Reliability and Operational Stability
The AFEX-950 automatic ambient air quality monitoring station is designed for long-term, continuous operation in harsh industrial conditions. Key Technical Specifications- Ingress protection: IP67
- Power supply: 220 V
- Energy consumption: ≤ 350 Wh
- Autonomous operation time: at least 24 hours
- Measurement error: ≤ 20%
- Zero drift: ≤ 0.1 MPC
- Service life: up to 10 years
Software Platform and Data Security
AFEX-950 runs on a modern software platform that ensures reliable data storage and security. Key Features- Data archive on a local server covering at least 24 months.
- Data encryption and authentication.
- Software platform with open configuration.
- Remote monitoring and control via a web interface.
- Audit logs and user rights management.
- Real-time data tracking.
- Analysis and reporting over various time periods based on historical data.
Additional Features
If required, the AFEX-950 system can be equipped with wind speed, wind direction, noise and other additional sensors. The system receives data from the monitoring device in real time, transmits it to the central server, stores it and presents it visually through a user-friendly web interface.
- Rapid alerts and notifications via Telegram.
- User-friendly control panel for administrators and users.
- Equipment installation and commissioning, software configuration and user training services.
User Authentication
Each user is given a personal login and password to access the system. This allows monitoring data to be viewed conveniently and securely. In line with the project's technical requirements, the system can be expanded with additional sensors, modules and equipment. This equipment is selected according to the customer's needs and supplied at additional cost. 1 - Gas sensors (Honeywell) — for 1 year Electrochemical sensors typically last 12 months, so they are purchased with a reserve.Additional Equipment and Sensors (optional, at additional cost)

- Parameter
- Model (Honeywell) · Quantity (1 year)
- NO₂
- Honeywell NO2 electrochemical · 1 pc
- NO
- Honeywell NO electrochemical · 1 pc
- NH₃
- Honeywell NH₃ electrochemical · 1 pc
- SO₂
- Honeywell SO₂ electrochemical · 1 pc
- CO
- Honeywell CO electrochemical · 1 pc
- O₃
- Honeywell O₃ electrochemical · 1 pc
- H₂S
- Honeywell H₂S · 1 pc
- PM2.5 / PM10
- Honeywell Particle Sensor · 1 pc
- O₂
- Honeywell O₂ Sensor · 1 pc
Unit 3
- Gas type / tool
- Concentration / Gas mixture · Cylinder
- Zero gas
- 99.999% N₂ or synthetic air · 2 L
- NO
- 50 ppm NO / N₂ · 2 L
- NO₂
- 20 ppm NO₂ / N₂ · 2 L
- NH₃
- 50 ppm NH₃ · 2 L
- SO₂
- 50 ppm SO₂ / N₂ · 2 L
- CO
- 100 ppm CO / N₂ · 2 L
- O₃
- Ozone generator (not a gas, a generator) · 1 pc
Unit 4
- Item
- Quantity (for 1 year / recommended)
- PTFE / Teflon sample line
- 10 m
- Particulate filter (0.5–1 µm)
- 3 pcs
- Moisture trap / dryer
- 1 pc
- Solenoid valve
- 1 pc
- Flow meter / Flow controller
- 1 pc
- Sample pump (diaphragm)
- 1 pc
- O-ring & fitting set
- 1 set
4 - Electronics and Server Components
- Item
- Quantity (recommended)
- Data logger / I/O module
- 1 pc
- Power supply
- 1 pc
- Industrial Ethernet switch
- 1 pc
- Industrial PC / controller fan
- 1 pc
- SD card / SSD (data backup)
- 1 pc
Unit 6
- Item
- Quantity (recommended)
- Calibration tubing set
- 1 set
- Pressure regulator (for gas cylinder)
- 1 pc
- Gas leak detector spray
- 1 pc
- Sensor cleaning kit
- 1 set
Quick price request
Leave your name and phone number — our specialist will take care of the rest.
Your data is never shared with third parties
Specifications
Data provided by the manufacturer; configuration may vary per order.
Air Quality Monitoring Device Sensors
14 parameters- 1
- O₂ · % VOL · Oxygen concentration · 0 ~ 25 % VOL
- 2
- PM2.5 · µg/m³ · Fine particulate matter · 0 ~ 500 µg/m³
- 3
- PM10 · µg/m³ · Particulate matter · 0 ~ 3000 µg/m³
- 4
- CO · ppm · Carbon monoxide · 0 ~ 1000 ppm
- 5
- CO₂ · ppm · Carbon dioxide · 0 ~ 5000 ppm
- 6
- H₂S · ppm · Hydrogen sulfide · 0 ~ 100 ppm
- 7
- NH₃ · ppm · Ammonia · 0 ~ 100 ppm
- 8
- O₃ · ppb · Ozone · 0 ~ 5000 ppb
- 9
- NO₂ · ppm · Nitrogen dioxide · 0 ~ 20 ppm
- 10
- SO₂ · ppm · Sulfur dioxide · 0 ~ 20 ppm
- 11
- HCl · ppm · Hydrogen chloride (HCl) vapors · 0 ~ 50 ppm
- 12
- Cl₂ · ppm · Chlorine gas · 0 ~ 10 ppm
- 13
- Temperature · °C · Ambient temperature · −45 ~ +125 °C
- 14
- Humidity · % RH · Relative humidity · 0 ~ 99 % RH
Additional Equipment and Sensors (optional, at additional cost)
10 parameters- Parameter
- Model (Honeywell) · Quantity (1 year)
- NO₂
- Honeywell NO2 electrochemical · 1 pc
- NO
- Honeywell NO electrochemical · 1 pc
- NH₃
- Honeywell NH₃ electrochemical · 1 pc
- SO₂
- Honeywell SO₂ electrochemical · 1 pc
- CO
- Honeywell CO electrochemical · 1 pc
- O₃
- Honeywell O₃ electrochemical · 1 pc
- H₂S
- Honeywell H₂S · 1 pc
- PM2.5 / PM10
- Honeywell Particle Sensor · 1 pc
- O₂
- Honeywell O₂ Sensor · 1 pc
Section 3
8 parameters- Gas type / tool
- Concentration / Gas mixture · Cylinder
- Zero gas
- 99.999% N₂ or synthetic air · 2 L
- NO
- 50 ppm NO / N₂ · 2 L
- NO₂
- 20 ppm NO₂ / N₂ · 2 L
- NH₃
- 50 ppm NH₃ · 2 L
- SO₂
- 50 ppm SO₂ / N₂ · 2 L
- CO
- 100 ppm CO / N₂ · 2 L
- O₃
- Ozone generator (not a gas, a generator) · 1 pc
Section 4
8 parameters- Item
- Quantity (for 1 year / recommended)
- PTFE / Teflon sample line
- 10 m
- Particulate filter (0.5–1 µm)
- 3 pcs
- Moisture trap / dryer
- 1 pc
- Solenoid valve
- 1 pc
- Flow meter / Flow controller
- 1 pc
- Sample pump (diaphragm)
- 1 pc
- O-ring & fitting set
- 1 set
4 - Electronics and Server Components
6 parameters- Item
- Quantity (recommended)
- Data logger / I/O module
- 1 pc
- Power supply
- 1 pc
- Industrial Ethernet switch
- 1 pc
- Industrial PC / controller fan
- 1 pc
- SD card / SSD (data backup)
- 1 pc
Section 6
5 parameters- Item
- Quantity (recommended)
- Calibration tubing set
- 1 set
- Pressure regulator (for gas cylinder)
- 1 pc
- Gas leak detector spray
- 1 pc
- Sensor cleaning kit
- 1 set
Parts and sections
Main parts and sections of the machine. Specifications for each are in the section above.
01
02Additional Equipment and Sensors (optional, at additional cost)
10 parameters
- Parameter: 1 year
- H₂S: Honeywell H₂S · 1 pc
- 03
4 - Electronics and Server Components
6 parameters
- Data logger / I/O module: 1 pc
- Power supply: 1 pc
Delivery and commissioning
From consultation to launch — four steps under contract.

Consultation
We define your needs, configure the line and prepare an offer.

Contract
Timeline, payment terms and warranty are fixed in the contract.

Delivery
The equipment is delivered from the manufacturer to your site.

Installation and training
Our specialists commission the equipment and train your operators.
Frequently asked questions
The most common questions about delivery, contracts and tracking.
Is it possible to track my orders online?
How long will the shipments be delivered?
What are the shipping methods available?
What is required of me to conclude a contract?
Let’s discuss your project together
Contact us for advice on choosing equipment, technical solutions and offers.
Follow our channels
New equipment, commissioning and production footage — on our official channels.